Slave wired remote control installation error (when two slave wired remote controls are installed), Normal operation option setting error (when normal operation is selected with the wired remote control for a ventilation system (ERV) that does not support the normal operation option), Automatic operation option setting error (when automatic operation is selected with the wired remote control for a ventilation system (ERV) that does not support the automatic operation option), Only detected by products with a temperature sensor, Indoor unit room temperature sensor error (open or short), Indoor unit heat exchanger temperature sensor error (open or short), Option error (option wasn't set up or option data error), Remote Control on/off Outdoor Unit Power Reset, No communication for 2 minutes between indoor units (Communication error for more than 2 minutes), Indoor unit receiving the communication error from outdoor unit, When sending the communication error from the outdoor unit, the mismatching of the communication numbers and installed numbers after completion of tracking (Communication error for more than 2 minutes), Error of electronic expansion valve close, 2'nd detection of high temperature discharge, Compressor down due to 6'th detection of freezing. -Input sensor error. E-149: Error due to AHU master indoor unit sensor setting. That has been 3 months ago. Fixed compl Sump temperature sensor breakaway, Fixed comp2 Sump temperature sensor breakaway, Fixed comp3 Sump temperature sensor breakaway, Comp.1 Sump temperature sensor(Short or Open), Compressor down due to freeze protection control, System stop due to overload protection control, Comp, down by the sump protection control, Comp, down by the discharge temperature sensor, Heating operation restricted at outdoor temperature over TheatJiigh value (default: 30 °C), Cooling operation restricted at outdoor temperature below Tcooljow value (default 0°Q, Forbid an operation during heat mode with refrigerant charging operation when outdoor temperature is over 15°C, Start prohibition by refrigerant pressure error, Error due to operation failure of inverter compressor, System stop due to OLP temperature control, Error due to abnormal rotation of the compressor or unconnected wire of compressor, Error on DC-Link voltage sensor (Short or Open), Outdoor unit EEPROM Read/Write error (Option), Outdoor unit EEPROM Read/Write error (H/W), Error on IPM Heat Sink sensor of inverter 1 (Short or Open), Error on input current sensor of inverter 1 (Short or Open), Error due to mismatching capacity of indoor and outdoor unit, Switch option setting error(rvot applied), Indoor unit floating S/V error(When 1“ detection), Indoor unit EEV close failure(When 1“ detection), Indoor unit EEV open failure(When 1“ detection), Communication cables of indoor and outdoor units, Wired remote controller communication error, Wired remote controller cables, Wired remote controller, Communication error between indoor unit and outdoor unit, Communication error between wired remote controller and indoor unit, Operation LED and reservation LED flickering (1Hz period), Operation LED and filter LED flickering (1 Hz period), Reservation LED filter LED alternating flickering (1Hz period), Reservation LED and filter LED flickering (1Hz period), Indoor and outdoor communication abnormal, Operation LED and reservation LED alternating flickering (1Hz period), Wired remote controller communication abnormal, Check of departure of indoor temperature sensor, Check of indoor exchanger sensor departure, Check of outdoor exchanger sensor departure, When the electrical heater is over heated, Check of heater temperature sensor departure, Error of temperature sensor in the indoor unit (Open/5hort), Error of setting option switches for optional accessories, Indoor/Outdoor unit Communication Time Out Error 60 Packet Over data, Communication Error between Outdoor Main and Inverter Micom, (Occurred after 1 minute detection in Main and Inverter), Indoor Unit Eva in Sensor (Open/Short Error), Outdoor Temp Sensor Error (Open/Short Error), CONDTemp. I have a problem in Samsung inverter split a.c unit.indoor unit show error E109.What its means and what should I do.please help. Mauro. Ventilation system (ERV) is not installed incase of outside gearing. Is there any direct light on the outdoor unit or any obstacle against it? Is the operation selected among the Dry / Turbo / Sleeping / Fan only Mode. Please tell me about 10ch error in Samsung 1.5ton. and the list goes on and on and on they even promised to replace it but that never eventuated…, its e203 communication error…lose or bad wire between indoor and outdoor unit. Called the person who installed it and he tells me he will come and look at . We also use third-party cookies that help us analyze and understand how you use this website. 29/07/2017 0 risposte Napoli ID richiesta: 142797. I keep call and he tells me next week . ); Trouble: The wind comes out but the heating/cooling is not performed. Permalink. to admin..i also have error code e485 input current sensor error..im a retired hvac tech but have very little exp on mini splits..from what i have read says check power i did that its ok..then said replace pcb which i have on order..could anything else cause it as i dont have tools anymore and samsung tech wont talk to me.i had to order the board through a samsung service company here..could condenser fan motor cause that error?..i found a code for bad motor online e458 but i dont get that just e485. Ricerca guasti DAIKIN – VERIFICHE ED OPERAZIONI DEVONO ESSERE ESEGUITE DA TECNICI QUALIFICATPECIALIZZATI. Condizionatore Samsung errore E4: cosa significa. Non riesco a trovarlo su nessun sito. Out of these, the cookies that are categorized as necessary are stored on your browser as they are essential for the working of basic functionalities of the website. Tipo di lavoro: Riparazione o manutenzione condizionatore. and Samsung make the worst air conditioners on the market. Grazie a tutti. All rights reserved. What should I do? E-654: Data error on remote controller (Memory read/write error), My latest error code was E2 o3 or 03 which being the 3rd summer without it working clearly means its a piece of Crap. Riavvio Automatico > In caso di interruzione dell’alimentazione elettrica, le unità, al ripristino procedono a … It is mandatory to procure user consent prior to running these cookies on your website. Samsung Supporto IT Who can help me ? E-163: Indoor unit’s remote controller option input is Incorrect or missing. C ontactez le service client Samsung … Codici errori climatizzatori samsung- Ricerca Tecniche per il controllo dell affidabilità dei caratteri (parità) o dei blocchi dei dati. Unplug and plug again the power source for 2 minutes. What could be the problem with a system please help. Comment:*document.getElementById("comment").setAttribute( "id", "ade8436854dfd09f261f79fdbb4a5313" );document.getElementById("g2bf16c3b0").setAttribute( "id", "comment" ); Save my name, email, and website in this browser for the next time I comment. Unità Interne Polivalenti Mono-Multi > Le unità interne della gamma SIRIUS possono essere usate in configurazione Mono con le relative unità esterne o anche quali terminali per le unità Multi (SIRIUS 9, 12, 18 IU). E-212: If the rotary switch (on the MCU) for address setting of the indoor unit has 3 or more of the same address, E-213: When total number of indoor units assigned to MCU is same as actual number of installed indoor units but there is indoor unit that is not installed even though it is assigned on MCU, E-214: When number of MCU is not set correctly on the outdoor unit or when two or more MCU was installed some of them have the same address, E-215: When two different MCU’s have same address value on the rotary switch. Is the filter clogged with dust or dirty? Samsung Split Type, Multi System and VRF System AC Error Codes and Troubleshooting; Outdoor LED Display Error and Check Method (12K/18K/24K)-Samsung Split System Air Conditioning Outdoor LED Light Errors, Explanation: Communication error (unable to receive data), Main checking Point/Remark: Communication cable connection, Explanation: Communication error (outdoor cannot communicate), Main checking Point/Remark: Another indoor unit or indoor PCB, Explanation: Indoor unit room temperature sensor error (Open/Short), Main checking Point/Remark: Room temperature sensor, indoor PCB, Explanation: Indoor unit heat exchanger in temperature sensor error (Open/Short), Main checking Point/Remark: Heat exchanger in sensor, indoor PCB, Explanation: Indoor unit heat exchanger out temperature sensor error (Open/Short), Main checking Point/Remark: Heat exchanger out sensor, indoor PCB, Explanation: Indoor unit heat exchanger in temperature sensor detached, Main checking Point/Remark: Heat exchanger in sensor, Explanation: Indoor unit heat exchanger out temperature sensor detached, Main checking Point/Remark: Heat exchanger out sensor, Explanation: Indoor unit heat exchanger in & out temperature sensor detached, Main checking Point/Remark: Heat exchanger in & out sensor, Explanation: Indoor unit fan motor malfunction, Main checking Point/Remark: Fan motor and cable, Explanation: More than 2 indoor units cool and heat simultaneously, Main checking Point/Remark: Another indoor unit operation mode, Main checking Point/Remark: Cable connection (Indoor & Outdoor unit), Explanation: The number of indoor unit mismatched, Main checking Point/Remark: Cable connection (another indoor unit & outdoor unit), SW01(outdoor), Explanation: Compressor discharge sensor error(Short/Open), Main checking Point/Remark:  Outdoor unit, Main checking Point/Remark: Outdoor unit (Error code). These cookies do not store any personal information. The standard temperature ±2˚C during the automatic operation. … Error code related to the Communications / Settings / HW (cont. Che cosa sta ad indicare il codice E4 che appare sul display dei condizionatore? Hi did you ever find out how to correct the E-201 error I have the same problem i have it wired correctly as per diagram ..Thanks. | View our. E-217: hen indoor unit is connected to a MCU port but indoor unit is assigned to a MCU and the switch on the port is set to Off, E-218: When there’s at least one or more actual number of indoor unit connection compared to number of indoor units assigned to MCU, E-219: Error on temperature sensor located on MCU intercooler inlet, E-220: Error on temperature sensor located on MCU intercooler outlet, E-221: Error on outdoor temperature sensor of outdoor unit, E-231: Error on COND OUT temperature sensor of main outdoor unit, E-251: Error on discharge temperature sensor of compressor 1, E-257: Error on discharge temperature sensor of compressor 2, E-262: Discharge temperature sensor of compressor 1 is detached from the sensor holder on the pipe, E-263: Discharge temperature sensor of compressor 2 is detached from the sensor holder on the pipe, E-266: Top sensor of compressor 1 is detached, E-267: Top sensor of compressor 2 is detached, E-269: Suction temperature sensor is detached from the sensor holder on the pipe, E-276: Error on top sensor of compressor 1 (Short or Open), E-277: Error on top sensor of compressor 2 (Short or Open), E-291: Refrigerant leakage or error on high pressure sensor (Short or Open), E-296: Refrigerant leakage or error on low pressure sensor (Short or Open), E-308: Error on suction temperature sensor (Short or Open), E-311: Error on temperature sensor of double layer pipe/liquid pipe(sub heat exchanger) (Short or Open), E-321: Error on EVI (ESC) IN temperature sensor (Short or Open), E-322: Error on EVI (ESC) OUT temperature sensor (Short or Open), E-323: Error on suction sensor 2 (Short or Open), E-346: Error due to operation failure of Fan2, E-347: Motor wire of Fan2 is not connected, E-348: Lock error on Fan2 of outdoor unit, E-353: Error due to overheated motor of outdoor unit’s Fan2, E-355: Error due to overheated IPM of Fan2, E-361: Error due to operation failure of inverter compressor 2, E-364: Error due to over-current of inverter compressor 2, E-365: V-limit error of inverter compressor 2, E-366: Error due to over voltage /low voltage of inverter PBA2, E-367: Error due to unconnected wire of compressor 2, E-368: Output current sensor error of inverter PBA2, E-369: DC voltage sensor error of inverter PBA2, E-374: Heat sink temperature sensor error of inverter PBA2, E-385: Error due to input current of inverter 2, E-386: Over-voltage/low-voltage error of Fan2, E-389: V-limit error on Fan2 of compressor, E-393: Output current sensor error of Fan2, E-399: Heat sink temperature sensor error of Fan2, E-400: Error due to overheat caused by contact failure on IPM of Inverter PBA2, E-407: Compressor operation stop due to high pressure protection control, E-410: Compressor operation stop due to low pressure protection control or refrigerant leakage, E-416: Compressor operation stop due to discharge temperature protection control, E-425: Phase reversal or phase failure (3Ø outdoor unit wiring, R-S-T-N ), connection error on 3 phase input, E-428: Compressor operation stop due abnormal compression ratio, E-438: EVI (ESC) EEV leakage or internal leakage of intercooler or incorrect connector insertion of EVI, E-440: Heating mode restriction due to high air temperature, E-441: Cooling mode restriction due to low air temperature, E-442: Refrigerant charing restriction in heating mode when air temperature is over 15 °C, E-443: Operation prohibited due to low pressure, E-446: Error due to operation failure of Fan1, E-447: Motor wire of Fan1 is not connected, E-452: Error due to ZPC detection circuit problem or power failure, E-453: Error due to overheated motor of outdoor unit’s Fan1, E-455: Error due to overheated IPM of Fan1, E-461: Error due to operation failure of inverter compressor 1, E-462: Compressor stop due to full current control or error due to low current on CT2, E-464: Error due to over-current of inverter compressor 1, E-465: V-limit error of inverter compressor 1, E-466: Error due to over voltage /low voltage of inveter PBA1, E-467: Error due to unconnected wire of compressor 1, E-468: Output current sensor error of inverter PBA1, E-469: DC voltage sensor error of inver PBA1, E-474: Heat sink temperature sensor error of inverter PBA1, E-485: Error due to input current of inverter 1, E-486: Error due to over voltage/low voltage of Fan, E-489: V-limit error on Fan1 of compressor, E-493: Output current sensor error of Fan1, E-499: Heat sink temperature sensor error of Fan1, E-500: Error due to overheat caused by contact failure on IPM of Inverter PBA1, E-503: Error due to alert the user to check if the service valve is closed, E-504: Error due to self diagnosis of compressor operation, E-505: Error due to self diagnosis of high pressure sensor, E-506: Error due to self diagnosis of low pressure sensor, E-560: Outdoor unit’s option switch setting error (when iinappropriate option switch is on), E-563: Error due to module installation of indoor unit with old version (Micom version needs to be checked), E-573: Error due to using single type outdoor unit in a module installation, E-601: Communication error between remote controller and the DVM Hydro unit / Hydro unit HT, E-602: Communication error between master and slave remote controller, E-604: Tracking error between remote controller and the DVM Hydro unit / Hydro unit HT, E-618: Error due to exceeding maximum numbers of Hydro unit installation (16 units), E-627: Error due to exceeding maximum numbers of wired remote controller installation (2 units), E-628: DMS↔Transmitter Communication Error, E-630: ERV wire remote controller normal ventilation option set error, E-631: ERVWire Remote controller auto ventilation option set error, E-632: Error when input the pulse except set the value of Pulse Width by PIM, E-633: Error caused by installing mixed models, E-652: Two wired remote controllers have been set to Master mode (COM1 wiring), E-653: Remote controller’s temperature sensor is disconnected or has problem, E-654: Data error on remote controller (Memory read/write error), E-701: Floating switch error on the indoor unit (1st detection), E-702: Error due to closed EEV of indoor unit (1st detection), E-703: Error due to opened EEV of indoor unit (1st detection), E-901: Error on the sensor of water inlet pipe (Short or Open), E-902: Error on the sensor of water outlet pipe (Short or Open), E-904: Error on water tank (Short or open), E-907: Error due to pipe rupture protection, E-908: Error due to freeze prevention (Re-operation is possible), E-909: Error due to freeze prevention (Re-operation is impossible), E-910: Water temperature sensor on water outlet pipe is detached, E-911: Flow switch off error, When the switch is turned off within 10 seconds after a pump starts its operation (Re-operation is possible), E-913: Six times detection for Flow Switch Error (Re-operation is not possible), E-914: Error due to incorrect thermostat connection, E-917: Water Tank Sensor Configutation Error, UP: Trial operation incompleted (UnPrepared) – It will be cleared when trial operation was executed for 1 hour or when automatic inspection is completed.